Rapid Self-Contained Biological Indicator for EO, 4h Results, 50/box

Rapid Self-Contained Biological Indicator for EO, 4h Results, 50/box

Regular price $238.00
Sale price Regular price
Bionova Rapid Self-Contained Biological Indicator for Ethylene Oxide sterilization processes, with Bacillus atrophaeus 10^6 spores per vial, with completed results in 4 hours, 50/box
FDA, Rapid Fluorescence

Product code: BI-BEO-4
OEM: BT110

Features
  • Rapid 4-Hour Readout: fluorescence-based readout.
  • UV Light Stimulation: detects Bacillus atrophaeus spore viability post-sterilization.
  • Single-Use SCBI: Self-Contained Biological Indicators (SCBI) comprising a polypropylene tube, a spore carrier, and a glass ampoule with culture medium. Components enclosed with a colored cap, emphasizing the design for one-time use.
  • Spore Population: each tube contains a population of Bacillus atrophaeus ATCC® 9372 spores inoculated on a spore carrier.
  • Ethylene Oxide Process Indicator: a Process Indicator on the label changes color (brown/bordeaux to green) when exposed to Ethylene Oxide, serving as a visual confirmation of sterilization exposure.
  • Barrier Permeable to Ethylene Oxide: the plastic cap with holes and a barrier is permeable to Ethylene Oxide, allowing the penetration of Ethylene Oxide, a crucial aspect for effective sterilization.
  • Visual Confirmation at 48 Hours: optional 48-hour visual color-change confirmation. Green to yellow indicates living spores, while blue confirms successful sterilization.
  • Optional 7-Day Readout: for initial validation, comparing results with 4-hour fluorescence data. Humidified environment needed to prevent medium drying if 7-day readout performed.
  • Monitoring Frequency: adheres to professional standards for monitoring sterilization loads. Emphasizes the use of appropriate biological indicators for optimal patient safety.
  • Shelf Life and Expiration: 2-year shelf life from manufacture under recommended storage.
  • Endpoint Stability Reaction: chemical indicator endpoint remains stable for a minimum of 6 months under recommended conditions.

Sold separately:
Bionova Incubator
Bionova MiniBio Auto-Reader Incubator

Explore Our FAQs for Helpful Answers

Find answers to common questions about this product, including features, specifications, and operation. Need more help? Our team is here to assist.

How often should I spore test my sterilizer?

The CDC recommends biological monitoring (spore testing) of each sterilizer at least weekly, and with every load that contains an implantable device. Your state or local regulations may require more frequent testing.