Skip to content

Free Ground Shipping on Orders Over $3000

Optional Andersen ETO Cartridge Abator for the EOGas 4PLUS

Andersen EOGas 4PLUS Ethylene Oxide Sterilizer

 

 

Product code: NANEOG4Plus


FDA-Cleared for Complex Endoscopes and Long Lumens

The EOGas 4PLUS is designed for terminal sterilization of difficult-to-sterilize medical devices, including duodenoscopes and colonoscopes. Powered by EO-Flexible Chamber Technology (EO-FCT), it uses a 17.6 g EO microdose—up to 90% less EO than traditional rigid-chamber systems.

The system supports active aeration in the same chamber, controlled-temperature air circulation, automatic door locking, and a touchscreen interface. When paired with the optional Andersen ETO Cartridge Abator, it provides near-zero-emissions performance for processing compatible heat- and moisture-sensitive instruments.

Key Features
  • FDA-cleared for terminal sterilization of complex long-lumen devices
  • EO-FCT using a 17.6 g microdose of EO per cycle
  • Near-zero emissions when paired with the Andersen ETO Cartridge Abator
  • Approximately 3.5-hour cycle achieving a 10⁻⁶ sterility assurance level
  • Active aeration in the same chamber with no device transfer required
  • Touchscreen interface with real-time cycle guidance
  • Automatic door locking during sterilization cycles
  • Process Challenge Device integrated into the purge probe for consistent biological indicator placement
EOGas 4PLUS Advantages
  • Compared with steam: Supports compatible heat- and moisture-sensitive devices that may be damaged by steam.
  • Compared with hydrogen peroxide (H₂O₂): Supports compatible complex and long-lumen devices.
  • Compared with traditional EO systems: Uses a lower EO dose with a smaller equipment footprint and reduced emissions.
EOGas 4 vs. EOGas 4PLUS
Category EOGas 4 EOGas 4PLUS
Positioning Proven EO sterilizer for long lumens and heat-sensitive devices Next-generation EO platform for complex endoscopes and high-risk devices
Primary Use General long-lumen and delicate-device sterilization Terminal sterilization of duodenoscopes, colonoscopes, and complex lumens
FDA Clearance Terminal sterilization of long-lumen devices Terminal sterilization of duodenoscopes and colonoscopes
Chamber Technology Traditional chamber EO-Flexible Chamber Technology (EO-FCT)
EO Dose per Cycle Low-dose EO 17.6 g microdose EO
EO Efficiency Reduced EO usage Up to 90% less EO than rigid-chamber EO systems
Lumen Compatibility Long-lumen capable Validated for working lumens longer than 1,100 mm
Sterility Assurance Level SAL 10⁻⁶ SAL 10⁻⁶
Cycle and Workflow Standard EO cycle Approximately 3.5-hour cycle with integrated aeration
Sterilization and Aeration Aeration supported Sterilization and aeration in the same chamber
Endoscope Optimization Not endoscope-specific Designed for flexible endoscopes, duodenoscopes, and colonoscopes
Environmental Impact Low EO emissions Near-zero emissions with the Andersen ETO Cartridge Abator
Process Monitoring Standard monitoring Process Challenge Device integrated into the purge probe
User Interface Standard controls Touchscreen with real-time cycle guidance
Safety Features Standard door safety Automatic door locking during the cycle
Temperature Control Controlled chamber environment Warm-air circulation for stable sterilization and aeration
Facility Fit ASCs, veterinary facilities, SPD departments, and outpatient facilities Hospitals, endoscopy centers, and advanced SPD departments
Cost Positioning Cost-effective EO solution Premium, compliance-focused system
Key Advantage Proven reliability and lower acquisition cost Lower EO usage and expanded device compatibility
Additional Clearances

The EOGas 4PLUS is also cleared for sterilization of metal, plastic, and fabric loads.

Sterility Assurance Level: SAL 10⁻⁶

Warranty: 12 months parts only