Home > Sterilizers > Steam Autoclaves > Class B Pre Post Vac >

New Tuttnauer Elara 11 Class B Pre-Post Vacuum Autoclave Steam Sterilizer with Printer


New Tuttnauer Elara 11 Class B Autoclave
 
 


No Longer Available



Availability: Refurbished Tuttnauer Elara11 Only
Product Code: NTELARA
Similar Products: Tuttnauer T-Edge 11 Autoclave

Description Technical Specs Literature
 
PLEASE SEE: Refurbished Tuttnauer Elara11 Class B Pre Post Vacuum Autoclave

NTELARA has been replaced with a new model: Tuttnauer T-Edge 11 Autoclave with 11" chamber. 5 trays. 7 gallon/27L volume
Product Code: NTEDGE11B


New Tuttnauer Elara 11 Class B Pre Post Vacuum Autoclave Steam Sterilizer with Printer - NO LONG AVAILABLE
WARRANTY: 24 months parts and labor

Designed for sterilization of wrapped, porous and hollow loads. The chamber volume is large, external dimensions are small, making it especially suitable for smaller clinics requiring a high turnover. The control system is smart and intuitive, easy to use and has a large memory for consistent and reliable performance.

Pre-vacuum phase efficiently removes air, resulting in the full penetration of steam into wrapped, porous and hollow loads. The post-vacuum drying phase ensures complete drying of wrapped porous loads and hollow instruments. This guarantees that even the most difficult loads will easily reach Sterility Assurance Level (SAL).

The Tuttnauer Elara 11 Class B autoclave offers 4 FDA cleared sterilization programs and 2 test programs, which are the Vacuum Test and the Bowie Dick Test.

Features:
  • Large 7.5 Gallon chamber within a small foot print. A perfect fit for standard 24 inch shelves or counters
  • Provided with 5 stainless steel trays and can also hold cassettes
  • Water filling from the front economizes on office space by eliminating the need to keep the top of the autoclave accessible

Efficient
  • Short cycle and high volume pre and post vacuum pump for perfect class B sterilization results
  • 316L grade stainless steel chamber and door with electro-polish finish
  • A built-in steam generator provides steam and facilitates a standby steam mode
  • The door closes smoothly and locks automatically

Safety Features
  • A cycle will not start unless the door is properly locked
  • An automated double locking safety device prevents the door from opening while the chamber is pressurized
  • An automatic safety shut-off prevents overheating of the chamber
  • The autoclave comes with safety pressure-release valves for the chamber and generator
Features

Why should I buy a Tuttnauer sterilizer?
Tuttnauer autoclaves have a reputation of excellence that is evident by their contemporary design, ease of use and reliability. Tuttnauer autoclaves offer the best warranty and in office support.

Which is the best autoclave for my office?
For those on a budget, Tuttnauer has a complete line of Manual autoclaves to fit every need.
For those desiring the utmost in sterilization efficiency and ease of use, Tuttnauer has a complete line of fully automatic sterilizers, which feature the EZ9 and EZ10 models.

Which type of sterilizer is better, a manual or automatic unit?
All Tuttnauer autoclaves have been engineered and manufactured to provide high quality sterilization for your office.

What are the benefits of a closed-door drying system?
Closed door drying offers a more efficient and thorough drying cycle, insuring that your instrument wraps come out of the autoclave dry.

Do I need a printer on my automatic autoclave?
While not required, a printer offers you a printed record of each cycle run. The record contains information about the temperature and pressure all during the cycle, as well as any messages that may have been generated by the system.

Why should I use distilled water?
Distilled water is free of minerals that would otherwise clog the sterilizer and create the need for more than the normal amount of cleaning.

Why are my spore tests failing?
The number one reason that a spore test fails is because air has become trapped in the sterilization chamber. Check that your unit is reaching the proper sterilization pressure. If it is, then cleaning the air jet should solve your problem.
Overloading your sterilizer can also cause this problem to occur, refer to your Operator’s Manual for proper loading instructions.

How often should I clean my sterilizer?
The more often you use your sterilizer the more frequently it should be cleaned. If your average usage is 20 cycles per week, then cleaning once per week is recommended. If you use your sterilizer only once or twice a week, then cleaning once per month is okay.

What should I use to clean my sterilizer?
The sterilizer has a vacuum pump and steam generator, not a pipe heater. Tuttnauer offers a cleaning product called
Chamber Brite or Chamber Shine spray, which is specifically designed for cleaning your sterilizer. It is recommended to use this product on a daily basis.
Please follow the instructions on the package for proper usage. (Please note that Duraclean liquid is not recommended.)


Why is my manual sterilizer taking a long time to fill the chamber with water?
This is probably the result of debris collecting in the multivalve or piping. To clear the plumbing, follow these instructions:
Fill the chamber with water.
Close the door, set the timer and begin a normal sterilization cycle.
Allow the pressure to build to 15 psi.
Turn the timer back to zero.
Turn the multivalve clockwise, without stopping, to the Fill Water position.
The piping should now be clean and water flow should have improved.

The buttons on the keypad of my automatic sterilizer do not respond.
If the display shows only drying time on the screen and the keypad is unresponsive, the unit is probably trying to complete a drying cycle. Press the Stop button for at least one second, the unit should beep and the drying cycle will end. The keypad should now respond to your instructions.

My sterilizer does not turn on.
Check that there is power to the outlet that the unit is plugged into.
Check that the power cord is plugged into the back of the autoclave and also into the wall outlet.
Check that the circuit breaker lever is in the up position. If the unit has fuses, check that the fuses are not blown.
Press in the small red reset button.
Make sure the green Start / Stop switch is in the start position.
If the unit still does not turn on, then there is an internal problem that requires a qualified technician to look at.

The timer on my manual machine does not ring.

If setting the timer to less than 15 minutes, make sure you first turn the timer past 15 minutes and then back to the desired time. This will cock the hammer for the bell. b. The bell hammer may have broken off and the timer needs to be replaced.

The pressure is not reaching 30 psi
Is the temperature set for 273ºF? A lower temperature setting will correspond to a lower pressure.
The voltage going to the machine may be low. A 120-volt unit needs to have a minimum of 115 volts to perform correctly. A 230-volt unit needs to have a minimum of 220 volts to perform correctly.
The unit may be out of calibration, please call your technician for service.
The unit may have bad heaters, please call your technician for service.

Why is there steam leaking from around the door?
The door may not be tightened completely. Tighten the door-locking device until it feels very snug. Try not to over tighten, as this will cause excess wear of the door gasket. The door gasket may be worn. If you see any cracking or other damage to the door gasket, you should replace it.

My manual sterilizer is not drying the pouches completely.

The instrument pouches may be too closely packed in the chamber. We recommend using a Tuttnauer Pouch Rack for proper spacing of the pouches.
You may be allowing the autoclave to sit too long after the sterilization cycle is completed. The cooling of the chamber and instruments allows for a moisture build up, causing a less efficient and more difficult drying. Make sure to turn the multivalve to the Exhaust / Dry position as soon as the bell rings, indicating the end of the sterilization stage.

My automatic sterilizer is not drying the pouches completely.
The instrument pouches may be too closely packed in the chamber. We recommend using a Tuttnauer Pouch Rack for proper spacing of the pouches.
If you have an EA or EZ unit, the HEPA filter may be clogged and need changing. See your Operator’s Manual for instructions.
If you have an E unit, cracking the door open will help.

Why is there water remaining in the bottom of the chamber when I open the door?
If you have a manual autoclave, this can happen if the unit is allowed to cool at the end of the sterilization cycle and the pressure drops below 10 psi before you turn the multivalve to Exhaust / Dry.
In either a manual or automatic autoclave, this can happen because one of the valves is defective allowing water to seep back into the chamber.

Why do I get a Low Water message on my sterilizer?
The water sensor at the back bottom of your sterilizer may need to be cleaned. Using a damp cloth or sponge and a gentle twisting motion, clean off the sides of the sensor. There may be an internal leak that is allowing water and steam to escape back to the reservoir, leaving the chamber low. Please have a technician check your unit.

Why do I hear a loud noise coming from the water reservoir?
This can be the safety valve blowing off. Make sure the sterilization temperature is not set above 274ºF. The safety valve may be weak and in need of replacement. Please call your technician to service the unit. back to top

Why can’t I unscrew the locking device on my sterilizer?

The door bellows pin may be stuck. Try tightening the locking device; this should release the pin so you can unscrew the device. If this does not work, then a technician will be required to repair the unit.

Why doesn’t the drain valve allow the water to drain from the reservoir?
The drain valve is probably clogged. Open the valve and blow air into the valve. This should cause the clog to travel back to the reservoir. Make sure you have a cloth covering the reservoir opening as the compressed air can cause water to shot out of the reservoir.

Why are my pouches turning brown and my plastics melting?
If these items are touching the inner wall of the chamber, this will happen because the chamber wall is very hot.Your chamber may not be filling with the right amount of water. Check the Operator’s Manual for instruction on how to check the pitch of the chamber and how to properly fill the chamber before sterilizing. For automatic sterilizers you may need to have the “automatic water fill” calibrated. For manual autoclaves you must be sure to turn the multivalve to STE before closing the door, otherwise the chamber water can be pushed back into the reservoir leaving the chamber low. There may be an internal steam leak that is allowing water to leak back into the reservoir. This will cause the chamber to overheat. A technician will need to check this. Make sure the door is tightened sufficiently and the door gasket is in good condition so no steam is able to escape. Do not set the timer for too long of a cycle time. This will cause the chamber to run out of water and overheat.
If this problem is occurring during the Drying Cycle, then the problem is most likely the result of a defective component and you should call Duraline 1-877-561-0500

Duraline Systems is a Certified Tuttnauer Warranty Repair Company.


Accessories
Door Gasket for Tuttnauer Elara11, Curved door Tuttnauer Chamber Brite Autoclave Cleaner - 10 Pack/Box Drain Hose for Tuttnauer EZPlus / Elara Replacement Tray Set for Elara 11, EZ11Plus
Price: $160.26

Add
Price: $75.00
10 packets/box

Add
Price: $33.35

Add
Price: $194.20

Add
Door Gasket for Tuttnauer Elara11 Chamber Brite Autoclave Cleaner Drain Hose for Tuttnauer EZPlus / Elara replacement-tray-set-for-elara-11-ez11plus

Share your knowledge of this product. Be the first to write a review »